House Rewiring in New Orleans, LA

Knob-and-tube, cloth-insulated and aluminum branch circuits replaced in shotguns, cottages and doubles, with plaster and trim treated as something worth preserving.

$5 - $14 per square footWhole-house rewire
FreeOn-site estimate
24/7Emergency line
We pullThe permit
New NM-B cable fished through the wall cavity of a New Orleans shotgun house during a rewire

Last updated: August 31, 2026

New Orleans Electrical Services connects homeowners and businesses with licensed electrical contractors who rewire older homes across New Orleans and Orleans Parish. House rewiring in New Orleans is rarely a clean sheet: it is almost always the removal of one or more obsolete wiring systems from a building that people are still living in, with plaster, heart pine and original trim that nobody wants opened up. The scope, the sequencing, and the price all follow from what is actually in the walls, which is why the first visit is a survey rather than a quote.

What we do on the first visit

Every house rewiring job starts the same way: we look before we quote. You get the cause in writing, a price that does not move once work begins, and the permit filed by us rather than by you.

  • Survey what is really there. Attic, under-house, panel, and a sample of boxes. Most houses here have two or three eras of wiring at once.
  • Scope it in tiers. Safety-critical first, then capacity, then convenience. You see prices for each tier and choose the line.
  • Rewire in zones. We work a zone at a time so you keep power in the rest of the house. Most families stay in place throughout.
  • Inspect, patch, and hand over. Parish inspection, then plaster and paint made good. You get a labelled directory and the permit record.

Three wiring eras, usually in the same house

The typical pre-war New Orleans house has been wired three times, and none of the old work was removed. Knob-and-tube from the 1920s still feeds the original bedrooms. A 1960s kitchen renovation added a run of early NM cable. Somebody in the 1990s put a modern circuit into the back addition. The panel is a patchwork of all three and there is no directory.

Knob-and-tube is the layer that most concerns insurers and most concerns us. It was used from roughly the 1880s to the 1940s, and the problem is not the ceramic hardware, which is durable, but the rubber-and-cloth insulation on the conductor. It embrittles with age, and heat and humidity accelerate that. It also has no equipment grounding conductor at all, which is why every outlet on it is two-prong, and why nothing with a metal case is safely grounded anywhere in that part of the house.

Aluminum branch circuits are the layer people miss. Aluminum was widely substituted for copper in branch wiring between roughly 1965 and 1975 when copper prices spiked. It is a perfectly good conductor; the failure is at the terminations. Aluminum has a higher coefficient of thermal expansion than copper, so every heating and cooling cycle works the screw terminal slightly looser. Over decades the connection becomes resistive, and a resistive connection carrying load becomes a hot connection inside a wall box.

What humidity and salt air do to conductor here

Gulf Coast conditions change the maintenance picture in ways that generic rewiring advice does not cover. Junction boxes in a raised-cottage under-house or a vented attic spend the summer in high humidity, and where salt air reaches them, particularly in Lakeview, Gentilly and the eastern parishes, the terminations corrode. Corroded terminations are resistive terminations. It is the same failure mechanism as loose aluminum, arrived at by a different route.

This is why we survey the under-house and the attic before quoting rather than pricing off square footage alone. What we are looking for is green or white oxidation at splices, conductors sagging out of their staples, splices made outside a box, and any point where a run has been extended with a twist and tape. In houses that have flooded, we are also looking at whether the water line reached any device box; conductor that has been submerged wicks moisture up inside the insulation and corrodes well above the visible line.

The practical result is that rewiring a house here is frequently more urgent than its age alone suggests, and occasionally less. We have surveyed 1930s houses with surprisingly sound 1970s copper throughout, and 1990s houses with a flooded crawlspace full of corroded splices.

Rewiring a house you are living in, without gutting it

The question everyone actually wants answered is how much of the house gets opened up. In a raised cottage or shotgun with attic access above and a walkable space below, the answer is surprisingly little: most runs drop down from the attic or up from below inside the wall cavity, and the openings are at device boxes you were going to replace anyway. Plaster medallions, picture rails and original millwork generally survive untouched.

The harder cases are slab-on-grade construction with no under-house, low-clearance attics over an addition, and balloon-framed walls with fire blocking. There we fish where we can, use surface raceway in utility spaces where it is honest to do so, and cut and patch where there is no alternative. We show you where those openings will be before we start, not after.

Sequencing keeps you in the house. We rewire in zones, typically two or three rooms at a time, so the rest of the house stays energized. A whole-house rewire on a 1,400 square foot shotgun usually runs one to two weeks of working days. Kitchen and bath circuits get scheduled around your actual life rather than left dead over a weekend.

What is included

  • Room-by-room survey of what wiring systems are actually present
  • Written scope splitting must-do from can-wait, with prices for each
  • New NM-B (Romex) or MC cable on properly sized circuits
  • Grounded receptacles throughout, replacing two-prong devices
  • AFCI and GFCI protection per NEC 210.12 and 210.8
  • Dedicated circuits for kitchen, laundry, and fixed appliances
  • Old knob-and-tube de-energized and removed, not just abandoned live
  • Permit, inspection, and patching of every opening we make

What you should expect to pay

2026 whole-house rewire market data of $4-$15 per square foot. A 1,400 sq ft New Orleans shotgun lands around $7,000-$19,600; a 2,000 sq ft raised cottage around $10,000-$28,000.

JobRange
Whole-house rewire$5 - $14 per square foot
Panel replacement, same amperage$1,200 - $2,400
Electrical permit$50 - $300

The spread is driven by access more than by square footage. A raised cottage with a walkable under-house and a full attic sits at the low end. A slab-on-grade double with plaster walls, no attic clearance and original millwork sits at the high end because every run has to be fished and every opening patched.

Run the cost estimator for a range against your own situation, or call 504-336-6748 and describe the job.


DIY, cheapest bid, or permitted work

What you are comparing DIY or handymanCheapest bidPermitted, code-compliant work
Permit and inspection No permit. Work is invisible to the parish and to your insurer.Often skipped to hit the price. You carry the liability.Permit pulled, inspection scheduled, record on file with the parish.
Insurance position after a fire Unpermitted electrical work is a common basis for a denied claim.Same exposure. The invoice does not prove code compliance.A passed inspection is documentary evidence the work met code.
Grounding and bonding Typically reuses whatever was there, including ungrounded runs.Bonded at the panel only. Water and gas bonding often missed.Grounding electrode system verified and brought to NEC 250.
GFCI / AFCI protection Added where convenient, not where code requires.Minimum devices to pass a glance, not a load calculation.Placed per NEC 210.8 and 210.12 for the actual room use.
Load calculation None. Panel is sized by guess or by what fits.Rule of thumb. Frequently undersizes for AC plus EV plus range.NEC Article 220 calculation on paper before anything is ordered.
What happens at resale Turns up in the inspection report and becomes a price negotiation.Same, plus no permit history to show the buyer.Permit record and inspection sign-off transfer with the house.
If it fails in two years Yours to fix.Warranty is only as durable as the company. Many are gone.Documented scope, materials and workmanship warranty.

Our process for house rewiring

Survey what is really there

Attic, under-house, panel, and a sample of boxes. Most houses here have two or three eras of wiring at once.

Scope it in tiers

Safety-critical first, then capacity, then convenience. You see prices for each tier and choose the line.

Rewire in zones

We work a zone at a time so you keep power in the rest of the house. Most families stay in place throughout.

Inspect, patch, and hand over

Parish inspection, then plaster and paint made good. You get a labelled directory and the permit record.

Get a written price for house rewiring

Call and describe the job, or send a photo. We give you a number in writing before any work starts, and we pull the permit ourselves.


Frequently asked questions

What does it cost to rewire a house in New Orleans?

Budget $5 to $14 per square foot, which puts a 1,400 square foot shotgun at roughly $7,000 to $19,600 and a 2,000 square foot raised cottage at roughly $10,000 to $28,000. Access drives the spread far more than size does. A new panel, if the existing one cannot carry the rewired load, is separate at $1,200 to $4,500.

Can I rewire part of the house instead of all of it?

Often, yes, and it is frequently the right call. Partial rewiring makes sense when one identifiable system is the problem, for example knob-and-tube confined to the original two bedrooms while the rest of the house is sound 1980s copper. It makes less sense when the wiring eras are interleaved, because you end up paying twice to open the same walls.

Do I have to move out?

Almost never. We work in zones so you keep power in the rest of the house, and we schedule kitchen and bathroom circuits around your routine. A whole-house rewire on a typical shotgun runs one to two weeks of working days with the family in place.

My insurer says they will not renew because of knob-and-tube. Is partial removal enough?

That depends entirely on the carrier, and you should get their answer in writing before you scope the work. Some accept certification that all knob-and-tube has been de-energized and removed from the accessible areas. Others require complete removal throughout, including runs buried in inaccessible cavities. We provide documentation of exactly what was removed and what was de-energized, which is what a carrier will ask for.

Do you pull the permit, or is that on me?

We pull it. Any work that alters a circuit, adds a circuit, or changes the service requires an electrical permit in Orleans Parish, and the permit has to be held by the contractor doing the work. We file it, schedule the inspection, and meet the inspector. You get a copy of the permit and the sign-off for your records, which is what your insurer and any future buyer will ask for.


Request a callback about house rewiring

Two short steps. Same-day callback.

So we can tell you the realistic arrival window.

In a hurry? Calling is faster — 504-336-6748

504-336-674824/7 emergency line